  • 3kW Hybrid Inverter
  • 3kW Hybrid Inverter
  • 3kW Hybrid Inverter
  • 3kW Hybrid Inverter

Description

  • 3kW DC24V/AC120V/60HZ
  • Integrated 80A MPPT charge controller
  • UPS and AC charger function
  • Short-circuit protection against overload
  • Under-voltage and over-temperature protection
  • Over voltage, battery reverse connection (optional)
  • High-low voltage protection
  • AC Charging current 0-35A, 50A option
  • Configurable to battery or utility priority
 
 

Specifications

Model

HI-1KW

HI-1.5 KW

HI-2KW

HI-3KW

HI-4KW

HI-5KW

HI-6KW

HI-8KW

HI-10 KW

HI-12 KW

Input

Rated Capacity

1KW

1.5KW

2KW

3KW

4KW

5KW

6KW

8KW

10KW

12KW

Peak Power

3KW

4.5KW

6KW

9KW

12KW

15KW

18KW

24KW

30KW

36KW

Commercial Power Range (VAC)

110V AC:83V-137V / 120V AC: 90V-150V

220V AC: 165V-275V/240V AC: 173V-287V

220V AC: 165V-275V

240V AC: 173V-287V

Main Input Frequency Range

45-65HZ

Solar

MPPT/PWM Solar Controller

30A/50A/60A/80A

80A/100A/120A

Solar Input

360W/720W/1440W/1920W/2400W/2880W/3840W

3840W/4800W/7680W/9600W

PV Input Voltage Range

14V-130V DC (12V SYSTEM)/38V-130V DC (24V SYSTEM)/ 72V-180V DC (48V SYSTEM)/144V-280V DC (96V SYSTEM)

  Battery

Type

Lead Acid (AGM, Gel) or Lithium

DC Voltage

12V/24VDC

24V/48V DC

48V/96V DC

DC Input Voltage Range

12V DC: 10.5-15.0V DC; 24V DC: 21-30V DC; 48V DC: 42.0-60.0V DC; 96V DC: 84-120V DC

Charger

AC Charging

5-35A (Custom set 40A 50A Options)

 

 

 

Output

Capable of Starting Electric Motor

0.5HP

1HP

1.5HP

2HP

3HP

AVR Voltage Range

110/120/220/230/240±10% (Autosensing)

Battery Over Voltage Protection

12V DC: 16.7V DC / 24V DC: 33.4V / 48V DC: 66.8V

Battery Over Voltage Alarm

12V DC: 15V DC / 24V DC: 30V / 48V DC: 60V

Battery Under Voltage Protection

12V DC: 10.5V DC / 24V DC: 21V / 48V DC: 42V

Battery Low Voltage Protection

12V DC: 10V DC / 24V DC: 20V / 48V DC: 40V

Transfer Time

Typical: 5ms (including detection time)

Temperature Protection

≥85°C alarm, ≥90°C machine shut off

Overload

IPS automatically shuts down if overload exceeds 120% of normal value for 10 seconds, IPS automatically resumes work if overload comes to rated load

Waveform

Pure Sine Wave

Frequency

Commercial power supply: shared frequency with the commercial inversion state: 60/50±0.5

Output Frequency Range (Electric supply mode)

Tracking automatically

Temper-ature

Operating Temperature

0-70°C

Thermal Method

Cooling fan is intelligent control ≤42°C fan rotates slowly to ≥ 45°C fan rotates fast

Physical Size

Dimensions (mm)

510*325*215

645*325*215

765*320*250

Weight (kg)

16

19

20

27

35

37

41

57

60

62

 

User Manual