Description
- 3kW DC24V/AC120V/60HZ
- Integrated 80A MPPT charge controller
- UPS and AC charger function
- Short-circuit protection against overload
- Under-voltage and over-temperature protection
- Over voltage, battery reverse connection (optional)
- High-low voltage protection
- AC Charging current 0-35A, 50A option
- Configurable to battery or utility priority
Specifications
Model |
HI-1KW |
HI-1.5 KW |
HI-2KW |
HI-3KW |
HI-4KW |
HI-5KW |
HI-6KW |
HI-8KW |
HI-10 KW |
HI-12 KW |
||
Input |
Rated Capacity |
1KW |
1.5KW |
2KW |
3KW |
4KW |
5KW |
6KW |
8KW |
10KW |
12KW |
|
Peak Power |
3KW |
4.5KW |
6KW |
9KW |
12KW |
15KW |
18KW |
24KW |
30KW |
36KW |
||
Commercial Power Range (VAC) |
110V AC:83V-137V / 120V AC: 90V-150V 220V AC: 165V-275V/240V AC: 173V-287V |
220V AC: 165V-275V 240V AC: 173V-287V |
||||||||||
Main Input Frequency Range |
45-65HZ |
|||||||||||
Solar |
MPPT/PWM Solar Controller |
30A/50A/60A/80A |
80A/100A/120A |
|||||||||
Solar Input |
360W/720W/1440W/1920W/2400W/2880W/3840W |
3840W/4800W/7680W/9600W |
||||||||||
PV Input Voltage Range |
14V-130V DC (12V SYSTEM)/38V-130V DC (24V SYSTEM)/ 72V-180V DC (48V SYSTEM)/144V-280V DC (96V SYSTEM) |
|||||||||||
Battery |
Type |
Lead Acid (AGM, Gel) or Lithium |
||||||||||
DC Voltage |
12V/24VDC |
24V/48V DC |
48V/96V DC |
|||||||||
DC Input Voltage Range |
12V DC: 10.5-15.0V DC; 24V DC: 21-30V DC; 48V DC: 42.0-60.0V DC; 96V DC: 84-120V DC |
|||||||||||
Charger |
AC Charging |
5-35A (Custom set 40A 50A Options) |
||||||||||
Output |
Capable of Starting Electric Motor |
0.5HP |
1HP |
1.5HP |
2HP |
3HP |
||||||
AVR Voltage Range |
110/120/220/230/240±10% (Autosensing) |
|||||||||||
Battery Over Voltage Protection |
12V DC: 16.7V DC / 24V DC: 33.4V / 48V DC: 66.8V |
|||||||||||
Battery Over Voltage Alarm |
12V DC: 15V DC / 24V DC: 30V / 48V DC: 60V |
|||||||||||
Battery Under Voltage Protection |
12V DC: 10.5V DC / 24V DC: 21V / 48V DC: 42V |
|||||||||||
Battery Low Voltage Protection |
12V DC: 10V DC / 24V DC: 20V / 48V DC: 40V |
|||||||||||
Transfer Time |
Typical: 5ms (including detection time) |
|||||||||||
Temperature Protection |
≥85°C alarm, ≥90°C machine shut off |
|||||||||||
Overload |
IPS automatically shuts down if overload exceeds 120% of normal value for 10 seconds, IPS automatically resumes work if overload comes to rated load |
|||||||||||
Waveform |
Pure Sine Wave |
|||||||||||
Frequency |
Commercial power supply: shared frequency with the commercial inversion state: 60/50±0.5 |
|||||||||||
Output Frequency Range (Electric supply mode) |
Tracking automatically |
|||||||||||
Temper-ature |
Operating Temperature |
0-70°C |
||||||||||
Thermal Method |
Cooling fan is intelligent control ≤42°C fan rotates slowly to ≥ 45°C fan rotates fast |
|||||||||||
Physical Size |
Dimensions (mm) |
510*325*215 |
645*325*215 |
765*320*250 |
||||||||
Weight (kg) |
16 |
19 |
20 |
27 |
35 |
37 |
41 |
57 |
60 |
62 |
User Manual